Cowlitz County Public Utility District About Construction Standards Construction Standards Font Size: Share Share on FacebookShare on X (Twitter)Share on PinterestShare on LinkedinShare on Email Feedback Print Accordion title Section 1: Guys and Anchors All Section 1 Standards 1-10 – 10M Down Guy 1-20 – 10M Sidewalk Down Guy 1-21 – 25M Sidewalk Down Guy 1-30 – 25M Down Guy 1-40 – 10M Overhead Span Guy 1-50 – 25M Overhead Span Guy 1-60 – Screw Anchors and Attachments 1-70 – Rock Anchor 1-71 – Cross Plate Anchor 1-80 – Pole Push Brace 1-90 – Pole Swamp Shoe 1-100 – Pole Bog Pad 1-110 – 115kV Vertical Strain Insulator Guying Arrangement Section 2: Transmission Line Construction All Section 2 Standards 2-10 – 115kV Side Post Tangent 2-10DG – Pole Drill Guide 2-10SP – Reduced Spacing 2-11 – 115kV Vertical Post Tangent 2-11DG – Pole Drill Guide 2-12 – 115kV Vertical Post Tangent 2-12DG – Pole Drill Guide 2-20 – 115kV Side Post Light Angle 2-20DG – Pole Drill Guide 2-20SP – Reduced Spacing 2-30 – 115kV Side Post Light Angle Double Circuit 2-30DG – Pole Drill Guide 2-30SP – Reduced Spacing 2-40 – 115kV Vertical Swinging Corner 2-40DG – Pole Drill Guide 2-40SP – Reduced Spacing 2-50 – 115kV Vertical Double Deadend Corner 2-50DG – Pole Drill Guide 2-50SP – Reduced Spacing 2-60 – 115kV Vertical Double Deadend with Side Posts 2-60DG – Pole Drill Guide 2-60SP – Reduced Spacing 2-70 – 115kV Horizontal Double Deadend 2-70DG – Pole Drill Guide 2-80 – 115kV Vertical Deadend 2-80DG – Pole Drill Guide 2-80SP – Reduced Spacing 2-90 – 115kV Ganged Switch 2-90DG – Pole Drill Guide 2-90SP – Reduced Spacing 2-100 – 115kV Suspension H-Structure 2-101 – 115kV Suspension H-Structure w/ Fiberglass Crossarm 2-110 – 115kV 3-Pole Double Deadend Tangent (Insulators Below Crossarms) 2-120 – 115kV 3-Pole Double Double Tangent (Insulators Above Crossarms) 2-130 – 115kV 3-Pole Double Deadend Corner (60-90 Angle) 2-140 – 115kV 3-Pole Double Deadend with Side Posts (60-90 Angle) 2-150 – 115kV Vertical Construction Phase Transposition 2-RSN – Reduced Spacing Notes Section 3: Three-Phase Primary Line Construction All Section 3 Standards 3-20 – Double Pin Composite Arm (Extra Heavy Duty) (Discontinued) 3-21 – Double Pin Composite Arm (Heavy Duty) (Discontinued) 3-22 – Double Pin Composite Arm (Tree-Wire) (Discontinued) 3-23 – Double Pin 5-11 B on Pole (Extra Heavy Duty) (Discontinued) 3-24 – Double Pin 5-11 B on Pole (Heavy Duty) (Discontinued) 3-25 – Double Pin 5-11 B on Pole (Tree-Wire) (Discontinued) 3-26 – 10FT Double Pin 5-11 B on Pole (Extra Heavy Duty) (Discontinued) 3-26A – 10FT Double Pin 5-11 B on Arm(Extra Heavy Duty) (Discontinued) 3-27 – 10FT Double Pin 5-11 B on Pole (Heavy Duty) (Discontinued) 3-27A – 10FT Double Pin 5-11 B on Arm (Heavy Duty) (Discontinued) 3-28 – 10FT Double Pin 5-11 B on Pole (Tree-Wire) (Discontinued) 3-28A – 10FT Double Pin 5-11 B on Arm (Tree-Wire) (Discontinued) 3-30 – Composite Arm Deadend (Extra Heavy Duty) (Discontinued) 3-31 – Composite Arm Deadend (Heavy Duty) (Discontinued) 3-32 – Composite Arm Deadend (Tree-Wire) (Discontinued) 3-33 – 10FT Composite Arm Deadend (Extra Heavy Duty) (Discontinued) 3-34 – 10FT Composite Arm Deadend (Heavy Duty) (Discontinued) 3-35 – 10FT Composite Arm Deadend (Tree-Wire) (Discontinued) 3-40 – Composite Arm Double Deadend (Extra Heavy Duty) (Discontinued) 3-41 – Composite Arm Double Deadend (Heavy Duty) (Discontinued) 3-42 – Composite Arm Double Deadend (Tree-Wire) (Discontinued) 3-43 – 10FT Composite Arm Double Deadend (Extra Heavy Duty) (Discontinued) 3-44 – 10FT Composite Arm Double Deadend (Heavy Duty) (Discontinued) 3-45 – 10FT Composite Arm Double Deadend (Tree-Wire) (Discontinued) 3-50 – 8FT Composite Buck Deadend (Extra Heavy Duty) 3-51 – 8FT Composite Buck Deadend (Heavy Duty) 3-52 – 8FT Composite Buck Deadend (Tree-Wire) 3-53 – 10FT Composite Buck Deadend (Extra Heavy Duty) 3-54 – 10FT Composite Buck Deadend (Heavy Duty) 3-55 – 10FT Composite Buck Deadend (Tree-Wire) 3-60 – Vertical Corner (Extra Heavy Duty) 3-61 – Vertical Corner (Heavy Duty) 3-70 – Vertical Deadend (Extra Heavy Duty) 3-71 – Vertical Deadend (Heavy Duty) 3-80 – Vertical Double Deadend Corner (Extra Heavy Duty) 3-81 – Vertical Double Deadend Corner (Heavy Duty) 3-90 – Compact Construction In-Line (Extra Heavy Duty) 3-91 – Compact Construction In-Line (Heavy Duty) 3-92 – Compact Construction In-Line (Tree-Wire) 3-100 – Compact Construction Angle 1-5° (Extra Heavy Duty) 3-101 – Compact Construction Angle 3-10° (Heavy Duty) 3-102 – Compact Construction Angle 3-8° (Tree-Wire) 3-110 – Compact Construction Angle 5-8° (Extra Heavy Duty) 3-111 – Compact Construction Angle 10-14° (Heavy Duty) 3-112 – Compact Construction Angle 9-13° (Tree-Wire) 3-120 – Vertical In-line with Post Insulators (Extra Heavy Duty) 3-121 – Vertical In-line with Post Insulators (Heavy Duty) 3-122 – Vertical In-line with Post Insulators (Tree-Wire) 3-130 – Alley Arm Single or Double 3-230 – Pole Mounted Primary Metering 3-240 – Platform Mounted Primary Line Regulators (219kVA and Smaller) 3-241 – Platform Mounted Primary Line Regulators (416kVA) 3-260 – Capacitor Bank 600 kVAR 3-269 – Switched Capacitor Bank 1500 kVAR w/ Floating Neutral 3-270 – 15kV Group Operated 900 Amp Switch 3-270WO – 15kV Group Operated 900 Amp Switch (w/o control arm) 3-320 – Repeater AMI 3-330 – DDE H-FRAME 3-501 – Tangent, 8ft Wood Arm, 0-1° 3-502 – Light Angle, 8ft Wood Arm, 1-5° 3-503 – BOP Tangent, 8ft Wood Arm, 0-1° 3-504 – BOP Light Angle, 8ft Wood Arm, 1-5° 3-505 – Tangent, 10ft Wood Arm, 0-1° 3-506 – Light Angle, 10ft Wood Arm, 1-5° 3-507 – NOA Tangent, 10ft Wood Arm, 0-5° 3-508 – BOP Tangent, 10ft Wood Arm, 0-1° 3-509 – BOP Light Angle, 10ft Wood Arm, 1-5° 3-510 – Tangent, Braceless 8ft Fiberglass Arm, 0-1° 3-511 – Tangent, Braceless 10ft Fiberglass Arm, 0-1° 3-512 – NOA Tangent, Braceless 10ft FG Arm, 0-5° 3-513 – Light Angle, Braceless 8ft Fiberglass Arm, 1-5° 3-514 – Light Angle, Braceless 10ft Fiberglass Arm, 1-5° 3-530 – 3 Phase OH Distribution Double Pin Angle, 8′ FG Arm, 5-11° 3-531 – 3 Phase OH Distribution Double Pin Angle, 10′ FG Arm, 5-11° 3-532 – 3 Phase OH Distribution Dbl Pin NOA Angle, 10′ FG Arm, 5-11° 3-533 – 3 Phase OH Distribution Dbl Pin BOP Angle, 8′ FG Arm, 5-11° 3-534 – 3 Phase OH Distribution Dbl Pin BOP Angle, 10′ FG Arm, 5-11° 3-601 – Single Deadend, 8ft Fiberglass Arm 3-602 – Single Deadend, 10ft Fiberglass Arm 3-603 – NOA Single Deadend, 10ft Fiberglass Arm 3-604 – Double Deadend, 8ft Fiberglass Arm 3-605 – Double Deadend, 10ft Fiberglass Arm 3-606 – NOA Double Deadend, 10ft Fiberglass Arm Section 4: V-Phase Primary Line Construction All Section 4 Standards 4-10 – Single Arm (Heavy Duty) 4-20 – Double Pin Composite Arm (Heavy Duty) 4-30 – Composite Arm Deadend (Heavy Duty) 4-40 – Composite Arm Double Deadend (Heavy Duty) 4-50 – Composite Arm Buck Deadend (Heavy Duty) 4-60 – Vertical Corner (Heavy Duty) 4-70 – Vertical Deadend (Heavy Duty) 4-80 – Vertical Double Deadend Corner (Heavy Duty) 4-90 – V-Phase Vertical Double Deadend (Heavy Duty) Section 5: Single-Phase Primary Line Construction All Section 5 Standards 5-10 – Single Arm (Heavy Duty – Neutral on Arm) 5-15 – Single PH TW SA 0-5 (Heavy Duty – Neutral on Arm) 5-20 – Double Pin Composite Arm (Heavy Duty – Neutral on Arm) 5-25 – Single PH TW SA 5-11 Double Pin (Heavy Duty – Neutral on Arm) 5-30 – Composite Arm Deadend (Heavy Duty – Neutral on Arm) 5-40 – Composite Arm Double Deadend (Heavy Duty – Neutral on Arm) 5-50 – Composite Arm Deadend Buck (Heavy Duty – Neutral on Arm) 5-60 – Single Pole Top Pin 5-62 – Single PH TW 0-5 Pole Top Pin 5-64 – Single PH 0-3 Single Fiberglass Bracket Underbuild (Trans) 5-70 – Double Pole Top Pin 5-72 – Single PH TW 5-11 Double Pole Top Pin 5-74 – Single PH 4-14 Single Fiberglass Bracket Underbuild (Trans) 5-80 – Vertical Corner (Heavy Duty) 5-90 – Vertical Deadend (Heavy Duty) 5-92 – Single PH Vertical Deadend From Twiggy Arm 5-100 – Vertical Double Deadend (Heavy Duty) 5-102 – Single-Phase Vertical Double Deadend (Tree Wire) 5-110 – Vertical Double Deadend Corner (Heavy Duty) 5-112 – Single PH Vertical Double Deadend (Corner, Tree Wire) 5-120 – Single PH Vertical Double Deadend From Twig Arm 5-150 – Single PH Line Regulator Pole Mounted (219KVA and Smaller) 5-160 – Single PH 25KV Trip Saver (Recloser) 5-170 – Single PH Circuit Protected O/H Transformer 5-180 – Single PH Conventional O/H Transformers Section 6: Three-Phase Underground Primary All Section 6 Standards 6-10 – 4-Inch Primary Riser 6-20 – 6-Inch Primary Riser 6-40 – 100 Amp Lightning Arrestor/Cutout Combo 6-50 – 900 Amp Hook Operated Switch 6-70 – 15kV Gang Operated 900 Amp Switch (Discontinued) 6-80 – Three-Phase Primary Pedestal 6-85 – Three-Phase Transformer Pad 6-90 – Deadfront Switchgear Vault Lid 6-91 – Deadfront Switchgear Vault Lid 90° Rotated 6-100 – Three-Phase Underground Primary 1000 MCM Splice Vault 6-110 – 110 Module Vault 6′ x 12′ Section 7: Single-Phase Underground Primary All Section 7 Standards 7-10 – 100 Amp Lightning Arrestor/Cutout Combo 7-40 – 2-Inch Primary Riser 7-50 – Single-Phase Primary Pedestal 7-80 – Pad-Mounted Transformer 7-85 – Transformer Box Pad 7-86 – Bollard Installation 7-87 – Hillside Barrier 7-90 – Transformer Box Pad Lateral Tie-In Section 8: Secondary & Service Entrances All Section 8 Standards 8-4 – Representative Meter Bases 8-5 – Approved Meter Bases 8-6 – Approved Commercial Meter Bases 8-7 – 200A Free Standing MB Opt 1 8-8 – 200A Free Standing MB Opt 2 8-9 – 320A MB Free Standing 8-10 – 2-1/2 Inch Secondary Riser 8-11 – UG Temporary Service 8-12 – Meter Base Location 8-13 – 200A MB Surface Mt Opt 1 8-14 – 200A MB Surface Mt Opt 2 8-15 – 320A MB Surface Mt 8-17 – OH Mast Installation 8-18 – OH Mast Guying and Bracing 8-19 – OH Gable Attachment 8-20 – 3-Inch Secondary Riser 8-21 – Single Phase CT Metering 8-22 – Single Phase CT Mounting Base 8-23 – Single Phase CT Metering, Post Mount 8-24 – Three Phase CT Metering 8-25 – 48″ X 48″ CT Metering Cabinet 8-26 – Three Phase CT Mounting Base 8-27 – Three Phase CT Metering, Post Mount 8-30 – 3-Phase Secondary Pedestal 8-32 – Secondary Pedestal 8-40 – Temporary Overhead Service 8-50 – Multi-unit Underground Service 8-60 – Multi-unit Meter Packs 8-70 – Electrical Room 8-80 – Commercial Ganged Metering 8-90 – Pull and Termination Enclosure, 1200A Max 8-110 – Underground Switchboard Termination, 400 – 3000A 8-120 – Switchboard Metering 400 – 3000A 8-130 – Direct Connect Meter Compartment 8-140 – CT Compartment, 1001 – 3000A 8-150 – CT Compartment, 0 – 1000A 8-160 – Switchboard CT Service Section 8-170 – Outdoor Switchboard Enclosure 8-180 – Remote Meter Switchboard 8-190 – Combo CT & Direct Metering 8-200 – Emergency or Standby Generator 8-210 – Flood Access Platform Section 9: OPGW and Fiber Optics All Section 9 Standards 9-50 – OPGW Tangent (NOA) 9-60 – OPGW Double Deadend 9-65 – OPGW DE SINGLE 9-70 – OPGW Tangent (NOP) 9-75 – OPGW DDE SINGLE 9-80 – OPGW Coil Bracket Section 10: Metering Diagrams All Section 10 Standards 10-101 – 100 Amp Single-Phase 2-Wire 120V (Existing Only) 10-102 – 200 Amp Single-Phase 3-Wire 120/240V or 240/480V 10-103 – 320 Amp Single-Phase 3-Wire 120V/240V 10-104 – 200 Amp Single-Phase 3-Wire 120/208V 10-105 – 200 Amp Single-Phase 3-Wire 240/480V 10-106 – 320 Amp Single-Phase 3-Wire Delta 240V or 480 V (Existing Only) 10-107 – 200 Amp Three-Phase 4-Wire Wye 120/208V or 139/240V or 277/480V 10-108 – 200 Amp Three-Phase 4-Wire Delta 120/240V or 240/480V 10-109 – Residential Single-C.T. Single-Phase 3-Wire 120/240V (Existing Only) 10-110 – Commercial Single-C.T. Single-Phase 3-Wire 120/240V (Existing Only) 10-111 – Dual-C.T. Single-Phase 3-Wire 120/240V 10-113 – Commercial C.T. Three-Phase 4-Wire Delta 120/240V 10-114 – Commercial C.T. Three-Phase 4-Wire Wye – 800 Amps Maximum 10-115 – Commercial C.T. Three-Phase 4-Wire Wye – Over 800 Amps 10-116 – Commercial C.T. Three-Phase 3-Wire Delta (Existing Only) 10-117 – Primary Metering Single-Phase 2-Wire 7.2kV Underground 10-118 – Primary Metering Single-Phase 2-Wire 7.2kV Overhead 10-119 – Primary Metering Three-Phase 4-Wire Wye 12.5kV Underground 10-120 – Primary Metering Three-Phase 4-Wire Wye 12.5kV Overhead 10-121 – Primary Metering Three-Phase 3-Wire Delta 12.5kV Overhead (Existing Only) Section 11: Engineering Practices All Section 11 Standards 11-01 – Pole Ground Installation 11-10 – Trench Cross Sections 11-100 – Primary Device Working Clearances 11-110 – Transformer Fire & Safety Clearances 11-200 – Early Fault Detection Distribution Installation 8ft Wood Arm 11-202 – Early Fault Detection Distribution Tap Installation 11-210 – Early Fault Detection Transmission HLP Installation Section 12: Materials Standards All Section 12 Standards 12-10 – Class 4 Wood Poles (30 and 35-Ft) 12-20 – Class 2 Wood Poles (40-65 Ft) 12-30 – Class H2 Wood Poles (70 and 120-Ft) 12-32 – Class H2-H3 Ductile Iron Poles, Pre-drilled (60-115 ft) 12-33 – Class 2 Ductile Iron Poles, Pre-drilled Guy Pole (35 ft) 12-40 – 8-Ft Composite Crossarm Light Angle (5-11 Degrees) 12-50 – 8-Ft Composite Double Dead End Crossarm 12-60 – 12-Ft Composite Double Dead End Crossarm 12-70 – Double Pin Insulator Mounting Bracket 12-80 – 8-Ft Wood Heavy Duty Crossarm 12-90 – 8-Ft Wood Extra Heavy Duty Crossarm 12-100 – 10-Ft Wood Distribution Crossarm 12-110 – 10-Ft Composite Light Angle Crossarm 12-120 – 10-Ft Composite DE Crossarm 12-150 – Overhead Connectors – Wedge Tap Connectors 12-151 – Stirrup Clamp Connectors Section 13: Joint Use Standards All Section 13 Standards 13-01 – Pole Attachments Overhead Minimum Clearances 13-02 – Pole Attachments Grounding Connections 13-03 – Pole Attachments Guy Wire Attachments 13-04 – Pole Attachments Minimum Clearance to Service and Roadway 13-05 – Pole Attachments Minimum Clearance Between Circuits 13-06 – Pole Attachments Climbing Space Requirements 13-07 – Communication Wireless Antenna Attachment Transmission Poles 13-08 – Communication Wireless Antenna Attachment Distribution Poles 13-09 – Communication Wireless Antenna Attachment Guy Stub Poles 13-10 – Pole Attachments PUD Fiber 13-11 – Pole Attachments PUD Fiber (Self Supporting DDE) 13-12 – Pole Attachments PUD Fiber (Self Supporting Drop) 13-50 – PUD ADSS Fiber – Tangent Clamp Attachment 13-52 – PUD ADSS Fiber – Double Deadend (0-30 degree) 13-53 – PUD ADSS Fiber – Double Deadend (30+ degrees) 13-54 – PUD ADSS Fiber – Single Deadend 13-61 – PUD ADSS Fiber – Slack Storage – In Span 13-63 – PUD ADSS Fiber – Splice Closure – In Span Standards Technical Notices 02/21/2019 – Customer-Owned Risers and Service Wire NESC Violations 06/16/2021 – Transformer Box Pad Use 06/07/2023 – Revisions to O/H Distribution Standards 06/18/2024 – Standard Distribution Pole Sizes 11/07/2024 – Use of Ground Rods 03/02/2026 – Switch Labeling Other Drawings BOX PAD – Transformer Box Pad Installation BRIDGE ATTACHMENT – Conduit Attachment Guidelines LATERAL TIE IN – Service Lateral Tie-In Guidelines
Font Size: Share Share on FacebookShare on X (Twitter)Share on PinterestShare on LinkedinShare on Email Feedback Print